Digital Input Port
Digital Output Port
Temperature Sensor Input
Humidity Sensor Input
Diff. Pressure Sensor Input
Refrigerator Compressor Control Step
Heater Control Step
Humidify Control Step
Dehumidify Control Step
Main Brower Fan on/off Control
Dehumidier Control Function
React Heater Temp. Sensor Input
React Heater Control Function
React Heater Control Step 4 -
React Fan on/off Control 1 -
10
12
2
1
1
2 4
7
4
4
1
OK
OK
OK
4
1
10
12
1
1
-
2
5
2
-
1
-
-
-
-
-
-
-
OK(P control)
OK(P control)
OK(P control)
OK(P control)
OK(P control)
-
-
-
-
-
-
-
OK
OK
OK (PID control)
OK (PID control)
OK (PID control)
OK (PID control)
OK (PID control)
OK
OK
OK
OK
OK
OK
OK
Trip / Alarm Recording Function
Schedule Run/Stop Function
Cool / Dehumidify Analog Control
Cooling Analog Control
Heating Analog Control
Humidify Analog Control
Diff. Pressure Analog Control
Temperature Retransmission Output
Humidify Retransmission Output
Diff. Press. Retransmission Output
React Heater SCR on/off Control
Heater SCR on/off Control
Humidify Heater SCR on/off Control
Cooling State on/off Control
Main Specication
Models Models
Main Specication
DX100DX120 DX120DX140 DX140
DX100 series based on microprocessor has realized the best control and stability with efcient
control for HVAC units (AHU, constant temperature & humidity unit and control (dehumidier) and
perfect interface with safety devices. Its elegant graphic LCD display and LED helps users to check
the current state of the units.
- Temperature & humidity control function, Max. 6 loop of independent step
operating function
- Alternative operation by max. 4 compressors and 8 heaters
- Backup operating function
- Prevention from frequent starting failure occurred by low pressure hunting using
low pressure switch in compressor
- Successive starting function, pump down function and prevention from restarting
- Control function for cold water, hot water, steam valve, SCR, damper designed for
- Detection of error in temperature and humidity sensor, Alarm function, Output of
function
HVAC (4~20mA PID control)
of equipment state (Cooling and Dehumidication, Heating and Humidication)
- DX100 : HVAC Controller (2Comp) - DX120 : HVAC Controller (4Comp) - DX140 : Exclusive controller for constant temp. and humidity unit
MENU SELECT
RUN INFO
OPERATION
SCHEDULE
TRIP LOG
OPERATION
SET TEMPERATURE : 25.0°C
SET HUMIDIT Y : 50.0 %
COOL DIFFERENCE : 200 Pa
HEAT DIFFERENCE : 120
DEHUMIDITY DIFF
: 1.0
TRIP LOG
00 080102 15:55 FIRST POWER ON
01 080102 16:10 FAN FAULT
02 080102 16:30
COMP#1 FAULT
03 080102 16:30
COMP#2 FAULT
04 080102 16:45 HEATER FAULT
TRIP LOG STATE
COMP#1 FAULT ON 080102 16:30
TEMO : -20.0°C HUM : 15.0%
ID (10~1):
N (12~1):
08:20
08
STAND BY
25.0
25.0
PV SP
CM1SL 1
C1A LP1LP 2C2A RHAAFS
LOC STP
BRA RET
CM2SL2 ALR BROH1 H2 H3 H4 H5
C C
Current
Temperature
Set
Temp.
Temperature Single Control Display
08:20
08
DPS. ALARM
25.0
25.0
50.0
50.0
PV
SP
PV
SP
CM1SL1
C1A LP1LP2C2A RHAAFS
LOC STP
HUA BRA RET
CM2SL2 HUD ALR BROH1 H2 H3 H4 H5
C
%
Current Temperature
Set Temperature
Digital Output State
Operaon State
Digital Input State
Lock Signal
Current Humidity
Current Time
Set Humidity
Alarm Message
Equipment State Code
Temperature + Humidity Control Display
08
STAND BY
50.0
50.0
PV SP
CM1SL 1
C1A LP1LP 2C2A HUAAFS
LOC STP
BRA RET
CM2SL2 HUD ALR BRO
Current
Humidity
Set Humidity
%%
Humidity Single Control Display
X
08:20
DX100 / DX120 / DX140
HVAC Controller
DX Series
SENSETE°CH®
CWCHEAT-EDGE®
RAINBOW
SHIMADEN
PR ELECTRONICSSEKONIC
HUBA
KAISE
OHKURACORDEX
FRIED ELECTRIC
KIMO DOTECH
V-B6
Sensing
Technology
Corporation
457-B Boni Avenue New Zaniga Mandaluyong City
Tel No.
532-0088
Fax No.
531-7387
www.heatsenze.com